With the photoelectric sensing principle, this kind of detector is activated more quickly, accurately and reliably, and there are no false alarm due to chemicals, exhaust gas, wind and exterior light
Detector has passed EMC test, which greatly eliminates false alarms caused by interference from nearb sources
Pretty and jointless outward ดาวน์โหลดสเปค
CM-WT32L
Photoelectric Type Smoke Detector อุปกรณ์ตรวจจับควัน ชนิดโฟโตอิเล็กทริค
With the photoelectric sensing principle, this kind of detectors is activated more quickly, accurately and reliably, and there are no false alarm due to chemicals, exhaust gas, wind and exterior light
Detector has passed EMC test, which greatly eliminates false alarms caused by interference from nearby sources
Duo-LEDs display separately: Stand-by status: Green; Alarm status Red ดาวน์โหลดสเปค
Reflective Beam Detector is a reflective infrared beam smoke detector, which must be used together with reflectors. The number of reflector(s) to be used (1 to 4) depends on the distance of coverage from the detector
With built-in microprocessor, the detector has capabilities of analysis and judgment. The detector can automatically carry out system adjustment and compensation due to variations in ambience data, through fixed algorithm with indications by LED and signal through the output terminals
The detector sensitivity can be field adjustable, to increase the range of application
The detectors can be used with both Conventional Fire Alarm Panels, and GST range of Addressable Fire Alarm Panels ดาวน์โหลดสเปค
CM-WS14LR Rate of Rise Heat Detector อุปกรณ์ตรวจจับความร้อน ชนิดตรวจจับอัตราการเพิ่มของอุณหภูมิ
Dual LEDs for 360-degree visibility
Mechanical operating principles ensure the long-term durability and the least malfunction
Self-restoring function ensures the elements repeatedly use
Electrical contacts with Sliver-palladium alloy to conduct electricity excellently
The exhaust valve of R.O.R Heat Detector part uses optical fiber glass capillary tube that"s heat-resistant and moisture proof to avoid false alarms ดาวน์โหลดสเปค
CM-WS26L Rate of Rise Heat Detector อุปกรณ์ตรวจจับความร้อน ชนิดตรวจจับอัตราการเพิ่มของอุณหภูมิ
Mechanical operating principles ensure the long-term durability and the least malfunction Self-restoring function ensures the elements repeatedly use
The exhaust valve of R.O.R. Heat Detector part uses optical fiber glass capillary tube that"s heat-resistant and moisture-proof to avoid false alarms ดาวน์โหลดสเปค
Gas Detector อุปกรณ์ตรวจจับแก๊สรั่ว
2 Types of Gas Leak Detecting: Can detect LPG (liquefied petroleum gas) and LNG (natural gas and methane)
2 Types of Warning Messages: Both human voice message and built-in buzzer sound will warn you loudly when alarming
2 Functions of Auto-testing: Automatically detect sensor-failure and easy self-test button
2 Ways of Usage: Standalone type for household or wiring to control panel for monitoring system
3 Colors of Indicating Lights: Easy to read and can immediately tell different situations of Alarm/Fault/Normal
High Sensitivity: Smart combustible gas detector with built-in microprocessor control parts ดาวน์โหลดสเปค
CM-FP3 Fire Manual Call Point อุปกรณ์แจ้งเหตุด้วยมือ
Reusable: No glass to break. No consumables. Durable plastic push cover is reusable
Easy auto-reset: By pushing reset button to return to normal working condition
Phone jack function: For stable communication in any urgent time ดาวน์โหลดสเปค
CM-FP116Fire Manual Call Point อุปกรณ์แจ้งเหตุด้วยมือ
Protection against injury through glass pane
All plastics are fire-proof and stylish
Alarm triggering by breaking of the glass pane
Individual call point identification ดาวน์โหลดสเปค
Fire Alarm Bell 4 Inch กระดิ่งเตือนภัย
The way of motor-driven is taken at the low consumption of current to reduce the load for power output from receiver terminal
This design of exceptional structure is sturdy and durable. The bell even can ring to last 40 hours without decline of the performance and structure ดาวน์โหลดสเปค
CM-PBL Fire Alarm Complex อุปกรณ์แจ้งเตือนเพลิงไหม้ แบบคอมเพล็กซ์
The Fire Alarm Complex is a steel box, in which there are indication lamp, alarm bell and fire manual station.
In order to match the installation requirement, two types of surface mounting and recess mounting type are developed.
They can also be installed uprightly or transversely. Rush the button on fire manual station as soon as a fire accident found, the signal will be immediately transmitted to the fire receiver terminal. At the same time, the fire alarm bell will be ringing and the indication lamp will be also twinkling to give a warning. ดาวน์โหลดสเปค
CM-ST100A Electronic Bell อุปกรณ์แจ้งเหตุทางเสียง มีไฟกระพริบในตัว
Sound Output : Over 95dBA (at 1M), 100dBA (Normal)
Strobe : 15,000mcd, Super Bright LED, 6 pcs.
Tone : Bell Sound, Sweep, Siren, Emergent Whistle
Operating Current : 22mA(Typical), 30mA(Max.), 50-70mA(With Strobe) ดาวน์โหลดสเปค
CM-S103 Electronic Bell with strobe อุปกรณ์แจ้งเหตุทางเสียง มีไฟกระพริบในตัว
Sound Output : Over 95dBA (at 1M), 100dBA (Normal)
Strobe : 15,000mcd, Super Bright LED, 6 pcs.
Tone : Bell Sound, Sweep, Siren, Emergent Whistle
Operating Current : 50mA(Typical), 60mA(Max.) ดาวน์โหลดสเปค